Our Behnk Reagents
Simple. Stable. Reliable.
The Behnk reagents are characterized by simplicity and high quality with long stability time. As complete solution in combination with Behnk devices and validated applications we guarantee reliable high quality coagulation results in precision and accuracy.
Prothrombin Time (PT)
PT reagent Thromboplastin from rabbit brain origin with a low or high ISI intended for in vitro determination of Prothrombin time according to Quick in citrated human plasma.
- Lyophilized Thromboplastin of rabbit cerebral tissue
- Reconstitution diluent included in the set.
- Ready to use right after reconstitution.
- Low ISI: 1.1 to 1.3
- No interferences with: Triglycerides <731 mg/dL, Bilirubin <228 µmol/L, Hemoglobin <258 µmol/L, Low molecular weight Heparin <0.114 IU, Unfractionated Heparin <0.038 IU
Stability (reconstituted): 7 days at 2 – 8 °C
OBS
72 h at 18 – 22 °C
8 h at 37 °C
Box sizes:
REF 771100: RE 5 x 5 ml; DIL 2 x 15 ml
REF 771101: RE 8 x 12 ml; DIL 8 x 12 ml
- Lyophilized Thromboplastin of rabbit cerebral tissue
- Reconstitution diluent included in the set.
- Ready to use right after reconstitution.
- High ISI: 1.5 to 1.7
- No interferences with: Triglycerides <774 mg/dL, Bilirubin <162 µmol/L, Hemoglobin <258 µmol/L, Low molecular weight Heparin <0.114 IU
Stability (reconstituted): 5 days at 2 – 8 °C
OBS
24 h at 18 – 22 °C
8 h at 37 °C
Box sizes:
REF 771150: RE 5 x 5 ml; DIL 2 x 15 ml
REF 771151: RE 8 x 12 ml; DIL 8 x 12 ml
Activated Partial Thromboplastin Time (APTT)
APTT reagent containing phospholipids Cephalin from rabbit brain origin and contact activator Kaolin or Silica intended for in vitro determination of activated partial thromboplastin time in citrated human plasma.
- Lyophilized Cephalin (rabbit cerebral tissues) and activator Kaolin
- Calcium chloride solution included in the set.
- Ready to use right after reconstitution.
- The use of Kaolin minimizes the reading time and optimizes the optical detection.
- Insensitive to lupus anticoagulant
- No interferences with: Triglycerides <731 mg/dL, Bilirubin <133 µmol/L, Hemoglobin <261 µmol/L
Stability (reconstituted): 30 days at 2 – 8 °C
OBS
240 h at 18 – 22 °C
Box sizes:
REF 771200: AC 5 x 3 ml; CC 2 x 10 ml
REF 771201: AC 8 x 10 ml; CC 8 x 10 ml
- Lyophilized Cephalin (rabbit cerebral tissues) and activator Silica
- Calcium chloride solution included in the set.
- Ready to use right after reconstitution.
- Insensitive to lupus anticoagulant
- No interferences with: Triglycerides <731 mg/dL, Bilirubin <124 µmol/L, Hemoglobin <261 µmol/L
Stability (reconstituted): 30 days at 2 – 8 °C
OBS
144 h at 18 – 22 °C
Box sizes:
REF 771250: AC 5 x 3 ml; CC 2 x 10 ml
REF 771251: AC 8 x 10 ml; CC 8 x 10 ml
Fibrinogen
Fibrinogen reagent Thrombin of animal origin and Kaolin intended for in vitro determination of Fibrinogen according to Clauss in citrated human plasma.
- Lyophilized Thrombin of animal origin
- Dilution buffer included in the set.
- Ready to use right after reconstitution.
- The ingredient Kaolin optimizes the optical detection.
- Linearity Range: 100 to 871 mg/dL
- No interferences with: Triglycerides <731 mg/dL, Bilirubin <496 µmol/L, Hemoglobin <261 µmol/L, Low molecular weight Heparin <2.00 IU, Unfractionated Heparin <1.66 IU
Stability (reconstituted): 7 days at 2 – 8 °C
OBS
24 h at 18 – 22 °C
Box sizes:
REF 771300: RE 5 x 2 ml; BU 2 x 15 ml
REF 771301: RE 10 x 5 ml; BU 8 x 15 ml
Thrombin Time (TT)
Thrombin reagent of bovine origin intended for in vitro determination of Thrombin time in citrated human plasma.
- Lyophilized calcified thrombin of bovine origin
- Approx. 1.5 NIH/mL thrombin after reconstitution
- No interferences with: Triglycerides <900 mg/dL, Bilirubin <43 µmol/L, Hemoglobin <246 µmol/L
Stability (reconstituted): 7 days at 2 – 8 °C
OBS
48 h at 18 – 22 °C
Box sizes:
REF 771400: RE 12 x 2 ml
D-Dimer
D-Dimer reagent is a latex based immunoassay intended for quantitative in vitro determination of D-Dimer in citrated human plasma.
- Ready to use latex reagent containing polystyrene particles coated with monoclonal antibodies.
- Dilution buffer and Calibrator are included in the set.
- Wavelengths 400 – 800 nm
- Measuring range 100 – 3200 ng/mL
- Cut-off 200 ng/mL
- Test with a sensitivity of 95 %, specificity of 64 % and negative predictive value (NPV) of 98 %
- No interferences with: Triglycerides <290 mg/dL, Bilirubin <855 µmol/L, Hemoglobin <1,86 mmol/L, Low molecular weight Heparin <100 U/mL, Unfractionated Heparin <100 U/mL
Stability (once opened):
8 weeks at 2 – 8 °C
2 weeks at 15 – 25 °C
OBS
120 h at 18 – 22 °C
Box sizes:
REF 771500: BU 3 x 7 ml; AC 3 x 4 ml; CAL 2 x 1 ml; DIL 2 x 7 ml
Coagulation Factor Assays
Deficient plasma of human origin intended for in vitro determination of Factor II, V, VII, X and Factor VIII, IX, XI, XII activity in citrated human plasma.
- Lyophilized plasma of human origin free of the specific factor by selective immune adsorption.
- Additional needed diluent BE Owren Buffer.
- PT Factors (Factor II, V, VII, X) no interferences with: Triglycerides <450 mg/dL, Bilirubin <228 µmol/L, Hemoglobin <258 µmol/L, Low molecular weight Heparin <0.114 IU, Unfractionated Heparin <0.038 IU
- APTT Factors (Factor VIII, IX, XI, XII) no interferences with: Triglycerides <731 mg/dL, Bilirubin <124 µmol/L, Hemoglobin <261 µmol/L
Stability (reconstituted): 8 h at 2 – 8 °C
OBS
4 h at 18 – 22 °C
Calibrators
Calibration plasma of human origin for quantitative in vitro determination of coagulation tests in citrated human plasma.
- Lyophilized citrated plasma of human origin
- Three different levels of calibration plasma for Prothrombin Time (%, INR)
- BE Cal Set values are traceable to WHO INTERNATIONAL STANDARD THROMBOPLASTIN, RABBIT, PLAIN (RBT) from NIBSC
Stability (reconstituted): 4 h at 2 – 25 °C
Box sizes:
REF 775200: CAL1 4 x 0.5 ml; CAL2 4 x 0.5 ml; CAL3 4 x 0.5 ml
- Lyophilized citrated plasma of human origin
- Calibration plasma for Fibrinogen and Coagulation Factors
- BE Cal Ref values are determined against its secondary standards of the corresponding primary International Standard for relevant parameters: SSC/ISTH Secondary Coagulation Standard NIBSC code: SSCLOT4
Stability (reconstituted): 4 h at 2 – 25 °C
Box sizes:
REF 775100: CAL 6 x 1 ml
Controls
Control plasma of human origin for quality control of in vitro coagulation tests in citrated human plasma.
- Lyophilized citrated plasma of human origin
- Control plasma for Prothrombin Time (PT %, INR, sec.), Activated Partial Thromboplastin Time (APTT sec.), Fibrinogen (mg/dL), Thrombin Time, Factor II (%), Factor V (%), Factor VII (%), Factor VIII (%), Factor IX (%), Factor X (%), Factor XI (%) and Factor XII (%)
Stability (reconstituted):
10 h at 2 – 25 °C
5 days at -20 °C
Box sizes:
REF 773100: CON 6 x 1 ml
- Lyophilized citrated plasma of human origin
- Control plasma for Prothrombin Time (PT %, INR, sec.), Activated Partial Thromboplastin Time (APTT sec.), Fibrinogen (mg/dL), Thrombin Time, Factor II (%), Factor V (%), Factor VII (%), Factor VIII (%), Factor IX (%), Factor X (%), Factor XI (%) and Factor XII (%)
Stability (reconstituted):
10 h at 2 – 25 °C
5 days at -20 °C
Box sizes:
REF 773101: CON 6 x 1 ml
- Lyophilized plasma of human origin enriched with D-Dimer
- Control plasma for immunoturbidimetric determination of D-Dimer (ng/mL DDU
Stability (reconstituted):
24 h at 20 – 25 °C
7 days at 2 – 8 °C
Box sizes:
REF 773200: CON 6 x 1 ml
- Lyophilized plasma of human origin enriched with D-Dimer
- Control plasma for immunoturbidimetric determination of D-Dimer (ng/mL DDU)
Stability (reconstituted):
24 h at 20 – 25 °C
7 days at 2 – 8 °C
Box sizes:
REF 773201: CON 6 x 1 ml
Cleaning Solution
Cleaning solution intended for cleaning the needle on Behnk automated systems in order to avoid cross contaminations.
- Cleaning solution, acid based
- Ready to use reagent suitable for all Thrombolyzer systems
- Storage at 2 – 25 °C
Stability (once opened):
OBS
6 days at 15 – 25 °C
Box sizes:
REF 771800: CL 16 x 15 ml
- Cleaning solution, Sodium hydroxide solution (NaOH), 1 mol/L
- Ready to use reagent suitable for all Behnk automated systems
- Storage at 2 – 25 °C
Stability (once opened):
OBS Thrombolyzer series
6 days at 15 – 25 °C
Caped with silicone cap for Thrombomate XRA
28 days on board
Box sizes:
REF 050951: CL 16 x 15 ml
Buffers
Plasma dilution buffer intended for diluting plasma, calibrator and controls during the in vitro determination of coagulation tests.
- Dilution buffer for determination of Fibrinogen on semi-automated systems (plasma dilutions with 450 µl buffer on Thrombostat or 950 µl buffer on Thrombotimer).
- Same buffer as enclosed in the BE FIB set.
Stability (once opened):
OBS
6 days at 15 – 25 °C
Box sizes:
REF 771350: BU 16 x 15 ml
- Dilution buffer for determination of Factor II, Factor V, Factor VII, Factor VIII, Factor IX, Factor X, Factor XI and Factor XII
Stability (once opened):
OBS
6 days at 15 – 25 °C
Box sizes:
REF 771700: BU 16 x 15 ml
Kaolin
Additive reagent Kaolin intended for in vitro determination of Fibrinogen with third-party reagents in citrated human plasma.
- Additive reagent for Fibrinogen tests with third-party reagents
- Kaolin optimizes the optical detection
- Kaolin 3.0 g/l for fully automated systems, Thrombolyzer
- Kaolin 0.5 g/l for semi-automated systems, Thrombotimer
- Ready to use reagent
Stability:
Stored at 2-8 °C, until the expiry date stated on the label
Box sizes:
REF 050920: 1 x 100 ml Kaolin 0.5 g/l
REF 050940: 1 x 100 ml Kaolin 3.0 g/l
Contact us
Kommanditgesellschaft
Behnk Elektronik GmbH & Co.
Hans-Böckler-Ring 27
22851 Norderstedt
Germany
Phone: +49-40-52-98-61-0