LTA Reagents KITs

Standardized. Stable. Reliable.

The LTA reagent kits are characterized by standardization of reagents and their test concentrations according to ISTH recommendations which allow comparability between laboratories. As system reagent for Thrombomate XRA with test combinations for screening or special applications it guarantees high quality with long stability.

LTA 1 KIT

LTA 1 reagent with aggregation inductors Arachidonic acid (AA), Adenosine diphosphate (ADP), Collagen (Col), Epinephrine (EPI) and Thrombin receptor-activating peptide (TRAP) intended for in-vitro determination of platelet aggregation by light transmission aggregometry (modified Born method) in platelet rich plasma (PRP).

  • Standardized reagent combination for screening
  • Inductor concentrations according to ISTH recommendation
  • Lyophilized Arachidonic acid (AA) 1 mM / Test
  • Lyophilized Adenosine diphosphate (ADP) 2.5 µM / Test
  • Lyophilized Collagen (Col) 2 µg/ml / Test
  • Lyophilized Epinephrine (EPI) 5 µM / Test
  • Lyophilized Thrombin receptor-activating peptides (TRAP) 10 µM / Test
  • Diluent, Cleaning solution, cuvettes and balls enclosed in the kit
  • Sufficient for 70 screens

Stability (reconstituted): 28 days at 2 – 8 °C
REF 057301:

2 x LTA 1 Reagent Tray (5 x 1 ml)
2 x LTA Diluent 20 ml
2 x Clean Pro 15 ml
9 x LTA Cuvette Bars à 10 pcs
1 x Balls 2 mm à 900 pcs

LTA 2 KIT

LTA 2 reagent with aggregation inductors Arachidonic acid (AA), Adenosine diphosphate (ADP) and Collagen (Col) intended for in-vitro determination of platelet aggregation by light transmission aggregometry (modified Born method) in platelet rich plasma (PRP).

  • Standardized reagent combination for special applications
  • Lyophilized Arachidonic acid (AA) 1 mM / Test
  • Lyophilized Adenosine diphosphate (ADP) 5 µM / Test
  • Lyophilized Collagen (Col) 2 µg/ml / Test
  • Diluent, Cleaning solution, cuvettes and balls enclosed in the kit
  • Sufficient for 70 screens

Stability (reconstituted): 28 days at 2 – 8 °C
REF 057302:
2 x LTA 2 Reagent Tray (3 x 1 ml)
2 x LTA Diluent 20 ml
2 x Clean Pro 15 ml
6 x LTA Cuvette Bars à 10 pcs
1 x Balls 2 mm à 600 pcs

LTA 3 KIT

LTA 3 reagent with aggregation inductors Ristocetin (Ris) intended for in-vitro determination of platelet aggregation by light transmission aggregometry (modified Born method) in platelet rich plasma (PRP).

  • Standardized reagent combination for screening
  • Inductor concentrations according to ISTH recommendation
  • Lyophilized Ristocetin (Ris) 0.6 mg/ml / Test and 1.2 mg/ml / Test
  • Diluent, Cleaning solution, cuvettes and balls enclosed in the kit
  • Sufficient for 60 screens


Stability (reconstituted):
 28 days at 2 – 8 °C
REF 057303:
2 x LTA 3 Reagent Tray (1 x 1 ml)
2 x LTA Diluent 20 ml
2 x Clean Pro 15 ml
2 x LTA Cuvette Bars à 10 pcs
1 x Balls 2 mm à 200 pcs

LTA 4 KIT

LTA 4 reagent with aggregation inductors Arachidonic acid (AA), Adenosine diphosphate (ADP), Collagen (Col) and Ristocetin (Ris) intended for in-vitro determination of platelet aggregation by light transmission aggregometry (modified Born method) in platelet rich plasma (PRP).

  • Standardized reagent combination for special applications
  • Lyophilized Arachidonic acid (AA) 1 mM / Test
  • Lyophilized Adenosine diphosphate (ADP) 2.5 µM / Test and 5 µM / Test
  • Lyophilized Collagen (Col) 2 µg/ml / Test
  • Lyophilized Ristocetin (Ris) 0.6 mg/ml
  • Diluent, Cleaning solution, cuvettes and balls enclosed in the kit
  • Sufficient for 70 screens

Stability (reconstituted): 28 days at 2 – 8 °C
REF 057304:
2 x LTA 4 Reagent Tray (5 x 1 ml)
2 x LTA Diluent 20 ml
2 x Clean Pro 15 ml
9 x LTA Cuvette Bars à 10 pcs
1 x Balls 2 mm à 900 pcs

LTA 5 KIT

LTA 5 reagent with aggregation inductors Arachidonic acid (AA), Adenosine diphosphate (ADP), Collagen (Col) and Ristocetin (Ris) intended for in-vitro determination of platelet aggregation by light transmission aggregometry (modified Born method) in platelet rich plasma (PRP).

  • Standardized reagent combination for special applications
  • Lyophilized Arachidonic acid (AA) 1 mM / Test
  • Lyophilized Adenosine diphosphate (ADP) 2.5 µM / Test and 5 µM / Test
  • Lyophilized Collagen (Col) 2 µg/ml / Test
  • Lyophilized Ristocetin (Ris) 1.2 mg/ml
  • Diluent, Cleaning solution, cuvettes and balls enclosed in the kit
  • Sufficient for 50 screens

Stability (reconstituted): 28 days at 2 – 8 °C
REF 057305:
2 x LTA 5 Reagent Tray (5 x 1 ml)
2 x LTA Diluent 20 ml
2 x Clean Pro 15 ml
7 x LTA Cuvette Bars à 10 pcs
1 x Balls 2 mm à 900 pcs

Contact us

Kommanditgesellschaft
Behnk Elektronik GmbH & Co.
Hans-Böckler-Ring 27
22851 Norderstedt
Germany

Phone: +49-40-52-98-61-0
Fax: +49-40-52-98-61-99

E-mail: info@behnk.de